The chart below shows the recommended electrical specifications for each kiln model. If you are uncertain about your existing power, have it checked by an electrician. If you are installing a new kiln, have the electrician follow this guide.
Electrical requirements for Skutt Automatic Kilns
| Model |
Voltage |
Amp |
Watts |
Wire Size* |
Breaker Size |
Max Temp |
NEMA Receptacle |
 |
| GM10F |
115 |
15 |
1725 |
10 |
20 |
1800 |
5-15 |
| GM814 |
240 |
27.8 |
6660 |
8 |
40 |
1800 |
6-50 |
| GM814 |
208 |
32 |
6656 |
8 |
40 |
1800 |
6-50 |
| GM1014 |
240 |
34 |
8140 |
6 |
50 |
1800 |
6-50 |
| GM1014 |
208 |
39.1 |
8140 |
6 |
50 |
1800 |
6-50 |
| GM1414 |
240 |
34.7 |
8320 |
6 |
50 |
1800 |
6-50 |
| GM1414 |
208 |
40 |
8320 |
6 |
50 |
1800 |
6-50 |
| GM1414 3ph |
240 |
20 |
8320 |
10 |
30 |
1800 |
15-50 |
| GM1414 3ph |
208 |
23.1 |
8320 |
10 |
30 |
1800 |
15-50 |
| GM818 |
240 |
27.8 |
6660 |
8 |
40 |
1800 |
6-50 |
| GM818 |
208 |
26.7 |
5550 |
8 |
40 |
1800 |
6-50 |
| GM1018 |
208 |
40 |
8320 |
6 |
50 |
1800 |
6-50 |
| GM1027 |
240 |
48 |
11520 |
6 |
60 |
1800 |
6-50 |
| GM1027 |
208 |
48 |
9980 |
6 |
60 |
1800 |
6-50 |
| GM1027 3ph |
240 |
29.3 |
11520 |
8 |
40 |
1800 |
15-50 |
| GM1027 3ph |
208 |
31.7 |
11000 |
8 |
40 |
1800 |
15-50 |
| GM1227 |
240 |
48 |
11520 |
6 |
60 |
1800 |
6-50 |
| GM1227 |
208 |
48 |
9980 |
6 |
60 |
1800 |
6-50 |
| GM1227 3ph |
240 |
29.3 |
11520 |
8 |
40 |
1800 |
15-50 |
| GM1227 3ph |
208 |
31.7 |
11000 |
8 |
40 |
1800 |
15-50 |
| GM22CS |
240 |
31 |
7450 |
6 |
40 |
1800 |
6-50 |
| GM22CS |
208 |
35.8 |
7450 |
6 |
40 |
1800 |
6-50 |
| GM22CS 3ph |
240 |
17.9 |
7450 |
10 |
30 |
1800 |
15-50 |
| GM22CS 3ph |
208 |
20.7 |
7450 |
10 |
30 |
1800 |
15-50 |
All Skutt
kilns are equipped with a type K thermocouple.
*For each additional 50 feet use heavier wire, numerically two numbers
lowerfor example, instead of #10, use #8. If you anticipate installing
any larger kiln in the future, use the heavier wire.
|